2. MEASURE CLEARANCE OF REVERSE IDLER GEAR AND
SHIFT ARM SHOE
Using a feeler gauge, measure the clearance between the
reverse idler gear and shift arm shoe.
Standard clearance: 0.20 — 0.41 mm
(0.008 — 0.0161 in.)
Maximum clearance: 0.9 mm (0.0354 in.)