← 143AT · 144

AT-144 AUTOMATIC TRANSMISSION — Shift Lock System
3. INSPECT KEY INTERLOCK SOLENOID
(a) Disconnect the solenoid connector.
(b) Using an ohmmeter, measure the resistance between terminals.
Standard resistance: 12 — 17 Ω
(c) Apply the battery voltage between terminals.
At this time, confirm that a solenoid operation.
4. INSPECT SHIFT LOCK CONTROL SWITCH
Inspect that there is continuity between each terminals.
[TABLE:
Shift Terminal P P₁ P₂
Position
P range ○—○
(Release button is not pushed)
R, N, D, 2, L ranges ○ ○
]