BODY ELECTRICAL SYSTEM — Clock
BE-115
CLOCK
Troubleshooting
CLOCK WILL NOT OPERATE
Check to see if fuse is blown. → Blown fuse → Locate trouble and repair or replace fuse as necessary.
↓ OK
Check to see if clock adjusting button is sticking in position and has failed to return. → Adjusting button not returned → Repair if necessary or replace clock.
↓ OK
Check to see if battery voltage is over 11V with no load. → Below 11V → Recharge or replace battery.
↓ OK
Check to see if connector on clock side is loose or rusted. → Loose or rusted → Repair
↓ OK
Check to see if there is voltage at terminal B or connector or clock side. → No voltage → Locate cause and repair.
↓ OK
Check to see if clock ground wire is loose or rusted. → Loose or rusted → Repair
↓ OK
Replace clock.
CLOCK LOSES OR GAINS TIME
Check amount of time the clock loses or gains per day or a week against the allowable error table.
↓ Exceeds allowable error
Check to see if there is 11 — 15V on terminal B of connector on clock side. → Below 11V → Locate cause and repair, or recharge battery.
↓ OK
Adjust or replace clock.