Page text (OCR transcript)
AT-103 A340E(Others) AUTOMATIC TRANSMISSION - EXTENSION HOUSING EXTENSION HOUSING EXTENSION HOUSING INSPECTION AT06K-03 INSPECT EXTENSION HOUSING BUSHING Using a cylinder gauge, measure the inside diameter of the extension housing bushing. Maximum inside diameter: 40.09 mm (1.5783 in.) If the inside diameter is greater than the maximum, re- place the extension housing. AT7900