BE-44 BODY ELECTRICAL SYSTEM — Combination Meter
(b) Check that there is no continuity between the terminal and switch set screw with the parking brake lever returned.
If operation is not as specified, replace the switch.
Fasten Belt Warning
INSPECTION OF BELT WARNING
1. INSPECT WARNING LIGHT OPERATION
(a) Disconnect the connector from the fuse and relay block No.1(IG). Ground the terminal 6 on the wire harness side connector.
(b) Turn the ignition switch on. Check that the bulb lights.
If the bulb does not light, remove and test the bulb.
2. INSPECT BUCKLE SWITCH OPERATION
(a) Disconnect the connector from the switch.
(b) Check that there is no continuity between terminals of the switch with the belt unfastened.
(c) Check that there is continuity between terminals of the switch with the belt fastened.
If operation is not as specified, replace the switch.
3. INSPECT INTEGRATION RELAY OPERATION
(a) Connect the positive lead (+) from the battery to terminals 6 and 12.
(b) Connect the positive lead (+) from the battery to terminal 4 through a 3.4W test bulb.
(c) Ground terminal 3, check that the bulb lights and the buzzer sounds for 4 — 8 seconds.
(d) Connect the positive lead (+) from the battery to terminals 6 and 12.
(e) Connect the positive lead (+) from the battery to terminal 4 through a 3.4W test bulb.
(f) Ground terminals 3 and 5, check that only the bulb lights for 4 — 8 seconds.
If operation is not as specified, replace the relay.