(b) Using a press, press in a new front bearing.
3. INSPECT REAR BEARING
Turn each bearing by hand while applying inward force.
If resistance is felt or the bearing sticks, replace the bearing.
4. IF NECESSARY, REPLACE REAR BEARING
(a) Using SST, remove the bearing.
SST 09286–46011
(b) Using SST and a press, press in a new bearing.
NOTICE: Be careful of the bearing installation direction.
SST 09820–00030
Upward
SST
Downward
Magnetic Switch
1. DO PULL–IN COIL OPEN CIRCUIT TEST
Using an ohmmeter, check that there is continuity between
terminals 50 and C.
If there is no continuity, replace the magnetic switch.
Ohmmeter
Continuity
Terminal C
Terminal 50