INSPECTION PROCEDURE
1 Check voltage between terminals VF1 and E1 of data link connector .
VF1
TE1
E1
DLC1
P (1) Warm up engine to normal operating temperature.
(2) Connect terminals TE1 and E1 of data link connector 1.
(3) Connect positive probe to terminal VF1 and negative probe to terminal E1 of data link connector 1.
C (1) warm up the oxygen sensor by racing engine at 2,500 rpm for about 2 minutes.
(2) Then, still maintaining engine at 2,500 rpm, count how many times voltmeter fluctuates need between 0 and 5 V.
Result
Result
Needle fluctuates 8 times or more for every ten seconds | OK
Continue at 0 V | NG Type I
Continue at 5 V | NG Type II
P11364
NG
Type I
NG
Type II Go to step 7 .
2 Check voltage between terminals OX1 and E1 data link connector 1.
E1 OX1
DLC1
V
FI6652
P Warm up engine to normal operating temperature.
C Measure voltage between terminals OX1 and E1 of data link connector 1 when engine is suddenly raced to full throttle.
OK The voltage should be 0.5 V or higher at least once.
Hint Inspection should not take linger than 1 second.
NG
OK Go to step 7 .