(b) When reusing precoated parts, clean off the old
adhesive and dry with compressed air. Then apply the
specified seal lock adhesive to the bolt, nut or threads.
(c) Precoated parts are indicated in the component
illustrations by the "• " symbol.
7. When necessary, use a sealer on gaskets to prevent leaks.
8. Carefully observe all specifications for bolt tightening
torques. Always use a torque wrench.
9. Use of special service tools (SST) and special service
materials (SSM) may be required, depending on the nature
of the repair. Be sure to use SST and SSM where specified
and follow the proper work procedure. A list of SST and SSM
can be found in the preparation part at the front of each
section in this manual.
Medium Current Fuse and High Current Fuse
Equal Amperage Rating
BE1367
10. When replacing fuses, be sure the new fuse has the correct
amperage rating. DO NOT exceed the rating or use one with
a lower rating.
Illustration | Symbol | Part Name | Abbreviation
BE5594 | IN0365 | FUSE | FUSE
BE5595 | IN0366 | MEDIUM CURRENT FUSE | M-FUSE
BE5596 | IN0367 | HIGH CURRENT FUSE | H-FUSE
BE5597 | IN0367 | FUSIBLE LINK | FL
BE5598 | IN0368 | CIRCUIT BREAKER | CB