EG-249
ENGINE – SFI SYSTEM (2JZ–GE)
Ohmmeter
+B
HT
P11484
3. California only:
INSPECT HEATER RESISTANCE OF MAIN HEATED OXY-
GEN SENSORS
(a) Disconnect the oxygen sensor connectors.
(b) Using an ohmmeter, measure the resistance between the
terminals +B and HT.
Resistance:
At 20°C (68°F) 11–16 Ω
If the resistance is not as specified, replace the sensor.
Torque: 44 N·m (450 kgf·cm, 33 ft·lbf)
(c) Reconnect the oxygen sensor connectors.